Density measurement
Detectors, systems and inline meters
- From radiometric density gauges to Coriolis meters
- Non-contact or inline measurement of density and concentration
- Accurate density and concentration readings of liquids from highly abrasive slurries to viscous or very corrosive media and suspensions
OPTIMASS 7400
Coriolis mass flowmeter for advanced process applications
- High accuracy (±0.1%), for viscous, aggressive or shear-sensitive media; maintains operation over a wide range of gas fractions and complex flow conditions (EGMTM)
- CT: OIML R117, MI-005; API; hygienic certifications
- Flange: DN10…100 / ½…4", max. PN100 / ASME Cl 600; others
- 3 x 4…20 mA, HART®7, Modbus, FF, Profibus-PA/DP, PROFINET, PROFINET (Ethernet-APL), EtherNet/IP™, Bluetooth®
OPTIMASS 6400
Coriolis mass flowmeter for advanced process applications
- High accuracy (±0.05% flat), for cryogenic to high temperature media (-200…+400°C / -328…+752°F); maintains operation over a wide range of gas fractions and complex flow conditions (EGMTM)
- SIL 2/3; CT: OIML R117, R137, MI-005, MI-002; API, AGA; hygienic certifications
- Flange: DN10…300 / ½…12", max. PN 160 / ASME Cl 1500
- 3 x 4…20 mA, HART®7, Modbus, FF, Profibus-PA/DP, PROFINET, PROFINET (Ethernet-APL), EtherNet/IP™, Bluetooth®
LoopSeries LB 430
Radiometric detector for level and density
- Contactless and non-intrusive density measurement for mining applications
- Uses silicon multiplier technology for high accuracy, robustness and significantly reduced energy costs
- 2-wire design for ease of installation: wiring via the 4...20 mA current loop, no additional power wires necessary
- Optional external display for challenging installation environments
DuoSeries LB 474
Radiometric density system for standard applications
- Unique: radiometric density measurement with intrinsically safe power supply (full Ex-i)
- Easy, intuitive operation via touch screen
- 2-wire technology: only 2 wires in the field
- Advanced self-diagnostics and monitoring features
SENSseries LB 480 D
Radiometric density meter for challenging measuring tasks in density, concentration and solid content measurement
- Compact field probe with integrated transmitter
- Quick start menu for effective, fast and easy to use start-up
- Continuous self-monitoring through unique cosmic radiation control
- Patented 4...20 mA current output; process integration via HART®
SmartSeries LB 414
Radiometric detector for density, concentration and solids content in non-explosive areas
- Compact and cost-optimised field device with integrated transmitter
- Simple and straightforward local display operation
- No recalibration required
- Process connection via 4...20mA/HART®