HRSG exhaust gas flow in combined cycle power plant
HRSG exhaust gas flow in combined cycle power plant – Ammonia storage level measurement
HRSG exhaust gas flow in combined cycle power plant – Strainer resistance measurement
HRSG exhaust gas flow in combined cycle power plant – Plant air pressure monitoring
HRSG exhaust gas flow in combined cycle power plant – Strainer resistance measurement
HRSG exhaust gas flow in combined cycle power plant – Flow measurement of liquid ammonia
HRSG exhaust gas flow in combined cycle power plant – Flue gas temperature measurement
HRSG exhaust gas flow in combined cycle power plant – Pressure measurement of liquid ammonia
HRSG exhaust gas flow in combined cycle power plant – Monitoring of heat transfer section
HRSG exhaust gas flow in combined cycle power plant – Mass flow measurement of gaseous ammonia
HRSG exhaust gas flow in combined cycle power plant – Temperature measurement of diltuion gas
HRSG exhaust gas flow in combined cycle power plant – Flow measurement of dilution gas
HRSG exhaust gas flow in combined cycle power plant – Suppelemental fuel gas measurement
HRSG exhaust gas flow in combined cycle power plant – Flow measurement of each burner
HRSG exhaust gas flow in combined cycle power plant – Differential pressure measurement across catalyst
HRSG exhaust gas flow in combined cycle power plant – Balancing of ammonia injection
HRSG exhaust gas flow in combined cycle power plant – Temperature measurement of supplemental fuel
HRSG exhaust gas flow in combined cycle power plant – Gas temperature measurement in HRSG duct
HRSG exhaust gas flow in combined cycle power plant – Fuel gas pressure control
HRSG exhaust gas flow in combined cycle power plant – Gas temperature measurement in HRSG duct
HRSG exhaust gas flow in combined cycle power plant

Описание

Ammonia storage level measurement

Требования к данной позиции измерения

  • Ammonia also in gas phase
  • reliable measurement

Описание

Strainer resistance measurement

Требования к данной позиции измерения

  • Process control

Описание

Plant air pressure monitoring

Требования к данной позиции измерения

  • Process control

Описание

Strainer resistance measurement

Требования к данной позиции измерения

  • Process control

Описание

Flow measurement of liquid ammonia

Требования к данной позиции измерения

  • Chemical resistance
  • Accuracy long term stability

Описание

Flue gas temperature measurement

Требования к данной позиции измерения

  • Process control
  • Emission monitoring

Описание

Pressure measurement of liquid ammonia

Требования к данной позиции измерения

  • Process control

Описание

Monitoring of heat transfer section

Требования к данной позиции измерения

  • low measuring range, long term stability

Описание

Mass flow measurement of gaseous ammonia

Требования к данной позиции измерения

  • Combined mass flow and density measurement
  • Monitoring of evapuration process

Описание

Temperature measurement of diltuion gas

Требования к данной позиции измерения

  • Process control

Описание

Flow measurement of dilution gas

Требования к данной позиции измерения

  • Process control

Описание

Suppelemental fuel gas measurement

Требования к данной позиции измерения

  • longtime stability

Описание

Flow measurement of each burner

Требования к данной позиции измерения

  • High dynamic flow rates
  • transient flows
  • fast response

Описание

Differential pressure measurement across catalyst

Требования к данной позиции измерения

  • Process control

Описание

Balancing of ammonia injection

Требования к данной позиции измерения

  • Process control

Описание

Temperature measurement of supplemental fuel

Требования к данной позиции измерения

  • Process control

Описание

Gas temperature measurement in HRSG duct

Требования к данной позиции измерения

  • dynamic calculations
  • fast response

Описание

Fuel gas pressure control

Требования к данной позиции измерения

  • Process control

Описание

Gas temperature measurement in HRSG duct

Требования к данной позиции измерения

  • dynamic calculations
  • fast response

Overview

HRSG exhaust gas flow in combined cycle power plant

Duct burners and NOx removal

The Heat Recovery Steam Generator (HRSG) is designed to operate at the range of gas turbine exhaust conditions and constructed of gas tight components such as the exhaust gas inlet ducting, the casing and the exhaust gas stack. The system also includes dedicated measurement instruments for performance monitoring purposes. The gas turbine exhaust gas flows through the inlet ducting and the HRSG before being guided to atmosphere, via the exhaust gas stack. In this specific design, the HRSG key element heating surfaces installed in the following order, in the direction of the exhaust flow: HP Superheater 2, Reheater, HP Superheater 1, HP Economizer 3, HP Evaporator, IP Superheater, LP Superheater, HP Economizer 2, IP Evaporator, HP Economizer 1, LP Evaporator, Condensate Preheater.

Selective Catalyst Reactor (SCR)

Where the emission requirements are stringent, an SCR or CO catalyst system is located in the exhaust temperature section of the HRSG. The purpose of the SCR system is to convert the oxides of nitrogen (NOx) produced by the combustion turbine and the burner system to nitrogen and water vapor. The system consists of an ammonia supply unit, distribution manifold, injection grid, and catalyst bed to create an SCR reactor section.

Duct Burner

Duct burners are used to burn natural gas or oil in the gas turbine exhaust stream to increase the gas temperature and thus increase the steam output, in case the energy available in the gas turbine exhaust is not sufficient to meet system demands. The duct burner heats the exhaust gas to up to 800˚C. Duct burner systems consists of duct burner elements, the pilot and pilot fuel supply with igniters, and the main fuel supply which includes scanners, fuel gas metering, a cooling air system and a burner measurement and control system.

The OPTIFLEX 2200 guided radar is a reliable and maintenance free TDR level meter suitable for the measurement and control of ammonia levels in the ammonia storage tank. OPTIMASS 6400 is a sophisticated Coriolis mass flow meter to monitor the dosing of the gaseous ammonia to the AIG. Furthermore the density information from the OPTIMASS can be used to monitor the flawless operation of the ammonia evaporation process. The OPTISONIC 7300 ultrasonic gas flowmeter can cope with intermittent operation and transient flow changes of the fuel gas flow to the duct burners. KROHNE offers sophisticated instruments and solutions from single flowmeters up to flow computers and complete fuel gas skids.