Averaging pitot tube flowmeter

DP flowmeter for applications with liquids, gases and steam to high-temperature applications with dust-laden gases

  • Fast and easy installation without additional engineering, impulse lines and supports; the best retrofit capability
  • -200…+1150°C / -328…2102°F; max. 320 bar / 4641.2 psi (line pressure)
  • For line sizes DN50…2000 / 2…80" (larger on request)
  • 2-wire 4…20 mA/HART®, FF, Profibus-PA
OPTIBAR DP 7060 with averaging pitot tube
Averaging pitot tube with OPTIBAR DP 7060 differential pressure transmitter

Related products

OPTIBAR DP 7060

Differential pressure transmitter for flow, level, differential pressure, density and interface measurements

  • High performance DP transmitter with integrated line pressure measurement
  • Measuring range: 30 mbar…16bar / 0.44…232 psi; Line pressure: up to 700 bar / 10,153 psi
  • Reference accuracy of ±0.065%
  • 2-wire, 4…20 mA/HART®, FF, Profibus-PA, Bluetooth®
OPTIBAR DP 3050 - Differential pressure transmitter

Differential pressure transmitter for general flow, level and differential pressure applications

  • The most compact design in its class
  • Measuring ranges: 100 mbar…16 bar / 1.45…232 psi; Line pressure: up to 160 bar / 2320 psi
  • Reference accuracy ± 0.1%
  • 2-wire, 4…20 mA/HART®7
OPTIBAR PT 2000

Averaging pitot tube with multiple impact-sensing ports

  • Low pressure loss design; from basic to engineered solutions
  • Cryogenic to high temperatures possible (-200…+1000°C / -328…+1832°F); max. 160 bar / 2320.1 psi
  • For line sizes from DN50…2000 / 2…80" (larger on request)
  • Material: 1.4404 / 316L
OPTICHECK Pressure Mobile

Mobile app for pressure transmitters

  • Works with all OPTIBAR PM 5060, OPTIBAR PC 5060 and OPTIBAR DP 7060 equipped with Bluetooth display and adjustment module
  • Wireless device commissioning, verification and monitoring even in hard-to-reach areas
  • Parameterisation similar to PACTware DTM including remote SIL mode activation
  • Free download for iOS and Android
OPTIBAR FC 1000

Flow computer for process control of liquids, gases and steam

  • High performance flow and energy calculation with DP flow elements, volumetric or mass flowmeters
  • Compact design, quick and easy-to-operate via TFT touch screen
  • Enables split-range operation with two pressure transmitters for increased measuring dynamics
  • HART® communication with all common DP transmitters for loss-free measured data transmission and possibility of automatic zero point adjustment