Débitmètres électromagnétiques
Pour toutes les applications comportant des liquides conducteurs
Des mesures de débit simples aux mesures les plus exigeantes, y compris en transactions commerciales et sur les applications de sécurité (jusqu'à SIL 2/3)
Modèles et matériaux de revêtement pour diverses applications – depuis l'eau potable jusqu'aux liquides extrêmement collants, abrasifs ou agressifs
Large choix de diamètres nominaux, jusqu'à DN3000 / 120"
Electromagnetic flowmeter for dosing systems, compact skids and wireless on-site verification
- Multi Phase Operation (MPO): Continuous measurement and stable, repeatable readings – even during major process disturbances such as gas entrainment and solids
- Parameterisation, monitoring and verification via Bluetooth®
- Wafer design: DN10…150 / ⅜…6"; max. PN40 / ASME Cl 300
- Advanced OPTICHECK technology built-in diagnostics and NAMUR NE 107 status indication via colour-coded backlit display
Electromagnetic flowmeter for advanced water and wastewater applications and wireless on-site verification
- Integrated conductivity measurement with fast response time for monitoring water quality issues and empty pipe events
- Multi Phase Operation (MPO): Continuous measurement and stable, repeatable readings – even during major process disturbances such as gas entrainment and solids
- Parameterisation, monitoring and verification via Bluetooth®
- Flange: DN25…3000 / 1…120", max. PN40 / ASME Cl 300
- Advanced OPTICHECK technology built-in diagnostics and status indication via colour-coded backlit display
Electromagnetic flowmeter for advanced water applications without straight inlet/outlet runs (0D/0D)
- Integrated conductivity measurement with fast response time for monitoring water quality issues and empty pipe events
- Multi Phase Operation (MPO): Continuous measurement and stable, repeatable readings – even during major process disturbances such as gas entrainment and solids
- Parameterisation, monitoring and verification via Bluetooth®
- Flange: DN25…600 / 1…24", max. PN40 / ASME Cl 300
- Advanced OPTICHECK technology built-in diagnostics and status indication via colour-coded backlit display
Débitmètre électromagnétique pour les systèmes instrumentés de sécurité (SIS) et la haute précision
- Certifié pour les applications de sécurité jusqu'à SIL 2/3, avec une capacité de test partiel automatisée pour des intervalles étendus
- Meilleur intervalle de test de diagnostic de sa catégorie, y compris le temps de réponse aux défauts de seulement 2 minutes
- SIL 2/3 jusqu'à DN600 / 24" ; non-SIL jusqu'à DN2000 / 80" (plus grand sur demande)
- Impulsions, fréquence, état, 4...20 mA, HART®7
Electromagnetic flowmeter for advanced process applications, master metering and wireless on-site verification
- High accuracy meter (±0.15% of MV) with ceramic tube; suitable for aggressive and abrasive liquids and suspensions, incl. those with very high solid content, and temperatures up to +180°C / +356°F
- Multi Phase Operation (MPO): Continuous measurement and stable, repeatable readings – even during major process disturbances such as gas entrainment and solids
- Parameterisation, monitoring and verification via Bluetooth®
- Flange: DN15…300 / ½…12", max. PN40 / ASME Cl 300;
Wafer design: DN2.5...100 / ⅒...4" - Advanced OPTICHECK technology built-in diagnostics and NAMUR NE 107 status indication via colour-coded backlit display
Electromagnetic flowmeter for advanced hygienic applications and wireless on-site verification
- For precise flow measurement and dosing of food and beverage products – from soft drinks and milk to fruit concentrates
- Multi Phase Operation (MPO): Continuous measurement and stable, repeatable readings – even during major process disturbances such as gas entrainment and solids
- Parameterisation, monitoring and verification via Bluetooth®
- Meter size: DN2.5…150 / ⅒…6" (3A, EHEDG certified)
- Advanced OPTICHECK technology built-in diagnostics and NAMUR NE 107 status indication via colour-coded backlit display
Débitmètre électromagnétique pour applications de base avec liquides électroconducteurs
- Mesure économique du débit de liquides (≥5 μS/cm) jusqu'à +120°C
- Isolation supplémentaire des dispositifs électroniques, pour une utilisation dans des zones extrêmement humides
- Modèle sandwich (entre brides) : DN10…150 / ⅜…6", max. PN40 / ASME Cl 300
- 4…20 mA, impulsions, fréquence, état, HART®, Modbus
Débitmètre électromagnétique pour applications générales avec liquides electroconducteurs
- Mesure de débit économique des liquides (≥5 µS/cm) contenant une certaine teneur en solides (≤10%)
- -25…+120°C
- Modèle sandwich (entre brides) : DN10…150 / ⅜…6", max. PN40 / ASME Cl 300
- 4…20 mA, impulsions, fréquence, état, HART®
Débitmètre électromagnétique pour applications OEM, systèmes de dosage et ensembles montés compacts
- Mesure de débit économique des liquides (≥5 µS/cm) contenant une certaine teneur en solides (≤70%)
- -25…+120°C
- Modèle sandwich (entre brides) : DN10…150 / ⅜…6", max. PN40 / ASME Cl 300
- 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET
Débitmètre électromagnétique pour les applications de base sur l'eau et les eaux usées
- Matériaux de revêtement résistants aux produits chimiques à basse concentration
- Isolation supplémentaire des dispositifs électroniques, pour une utilisation dans des zones extrêmement humides
- Bride : DN25…1200 / 1…48", max. PN40 / ASME Cl 300
- 4…20 mA, impulsions, fréquence, état, HART®, Modbus
Débitmètre électromagnétique pour toutes les applications d'eau et d'eaux usées standards
- Matériaux de revêtement chimiquement résistants
- Version compacte jusqu'à IP69, version séparée IP68
- Bride : DN25…1200 / 1…48", max. PN40 / ASME Cl 300
- 4…20 mA, impulsions, fréquence, état, HART®
Débitmètre électromagnétique pour les utilités et l'automatisation industrielle
- Mesure de débit de liquides conducteurs, par ex. liquides de refroidissement, eau froide/chaude, produits chimiques, etc.
- Le meilleur de sa catégorie : plage de température, précision, perte de charge et échelle de débit
- Modèle ultra-compact pour installation parallèle et en espaces restreints
- 4…20 mA, impulsions, fréquence, Modbus, IO-Link
Visualisation de 12 sur 36