Electromagnetic flowmeters
For all applications with conductive liquids
From basic to demanding flow measurements, incl. custody transfer and safety-related applications (up to SIL 2/3)
Designs and liner materials for virtually any application – from potable water to extremely adhesive, abrasive and aggressive liquids
Large choice of nominal sizes up to DN3000 / 120"
Electromagnetic flowmeter for dosing systems, compact skids and wireless on-site verification
- Multi Phase Operation (MPO): Continuous measurement and stable, repeatable readings – even during major process disturbances such as gas entrainment and solids
- Parameterisation, monitoring and verification via Bluetooth®
- Wafer design: DN10…150 / ⅜…6"; max. PN40 / ASME Cl 300
- Advanced OPTICHECK technology built-in diagnostics and NAMUR NE 107 status indication via colour-coded backlit display
Electromagnetic flowmeter for advanced water and wastewater applications and wireless on-site verification
- Integrated conductivity measurement with fast response time for monitoring water quality issues and empty pipe events
- Multi Phase Operation (MPO): Continuous measurement and stable, repeatable readings – even during major process disturbances such as gas entrainment and solids
- Parameterisation, monitoring and verification via Bluetooth®
- Flange: DN25…3000 / 1…120", max. PN40 / ASME Cl 300
- Advanced OPTICHECK technology built-in diagnostics and status indication via colour-coded backlit display
Electromagnetic flowmeter for advanced water applications without straight inlet/outlet runs (0D/0D)
- Integrated conductivity measurement with fast response time for monitoring water quality issues and empty pipe events
- Multi Phase Operation (MPO): Continuous measurement and stable, repeatable readings – even during major process disturbances such as gas entrainment and solids
- Parameterisation, monitoring and verification via Bluetooth®
- Flange: DN25…600 / 1…24", max. PN40 / ASME Cl 300
- Advanced OPTICHECK technology built-in diagnostics and status indication via colour-coded backlit display
Electromagnetic flowmeter for safety instrumented systems (SIS), advanced process applications and wireless on-site verification
- Allows automated partial proof testing, extending proof test intervals in SIL applications
- Multi Phase Operation (MPO): Continuous measurement and stable, repeatable readings – even during major process disturbances such as gas entrainment and solids
- Parameterisation, monitoring and verification via Bluetooth®
- Flange: DN2.5…3000 / ⅒…120", max. PN40 / ASME Cl 600 (higher on request)
- Advanced OPTICHECK technology built-in diagnostics and NAMUR NE 107 status indication via colour-coded backlit display
Electromagnetic flowmeter for advanced process applications, master metering and wireless on-site verification
- High accuracy meter (±0.15% of MV) with ceramic tube; suitable for aggressive and abrasive liquids and suspensions, incl. those with very high solid content, and temperatures up to +180°C / +356°F
- Multi Phase Operation (MPO): Continuous measurement and stable, repeatable readings – even during major process disturbances such as gas entrainment and solids
- Parameterisation, monitoring and verification via Bluetooth®
- Flange: DN15…300 / ½…12", max. PN40 / ASME Cl 300;
Wafer design: DN2.5...100 / ⅒...4" - Advanced OPTICHECK technology built-in diagnostics and NAMUR NE 107 status indication via colour-coded backlit display
Electromagnetic flowmeter for advanced hygienic applications and wireless on-site verification
- For precise flow measurement and dosing of food and beverage products – from soft drinks and milk to fruit concentrates
- Multi Phase Operation (MPO): Continuous measurement and stable, repeatable readings – even during major process disturbances such as gas entrainment and solids
- Parameterisation, monitoring and verification via Bluetooth®
- Meter size: DN2.5…150 / ⅒…6" (3A, EHEDG certified)
- Advanced OPTICHECK technology built-in diagnostics and NAMUR NE 107 status indication via colour-coded backlit display
Electromagnetic flowmeter for basic applications with conductive liquids
- Cost-effective flow measurement of liquids (≥5 μS/cm) up to +120°C / +248°F
- Extra isolation of electronics for use in high humidity areas
- Wafer-style design: DN10…150 / ⅜…6", max. PN40 / ASME Cl 300
- 4…20 mA, pulse, frequency, status, HART®, Modbus
Electromagnetic flowmeter for general applications with conductive liquids
- Economical flow measurement of liquids (≥5 μS/cm) with solid content (≤10%)
- -25…+120°C / -13…+248°F
- Wafer-style design: DN10…150 / ⅜…6", max. PN40 / ASME Cl 300
- 4…20 mA, pulse, frequency, status, HART®
Electromagnetic flowmeter for OEM applications, dosing systems and compact skids
- Economical flow measurement of liquids (≥5 μS/cm) with solid content (≤70%)
- -25…+120°C / -13…+248°F
- Wafer-style design: DN10…150 / ⅜…6", max. PN40 / ASME Cl 300
- 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET
Electromagnetic flowmeter for basic water and wastewater applications
- Liner materials resistant to low concentrated chemicals
- With extra isolation of electronics for use in high humidity areas
- Flange: DN25…1200 / 1…48", max. PN40 / ASME Cl 300
- 4…20 mA, pulse, frequency, status, HART®, Modbus
Electromagnetic flowmeter for all standard water and wastewater applications
- Chemically resistant liner materials
- Compact version up to IP69, remote version IP68
- Flange: DN25…1200 / 1…48", max. PN40 / ASME Cl 300
- 4…20 mA, pulse, frequency, status, HART®
Electromagnetic flowmeter for utilities and industrial automation
- Flow measurement of conductive liquids, e.g. coolants, cold/hot water, chemicals, etc.
- Best-in class temperature range, accuracy, pressure drop and flow range
- Ultra-compact design for parallel installation and tight spaces
- 4…20 mA, pulse, frequency, Modbus, IO-Link
Showing 12 of 36