Conductivity standard solution

Calibration solution for conductivity sensors

  • Available conductivity standards: 15 µS/cm, 147 µS/cm, 1413 µS/cm and 25 mS/cm (at +25°C / +77°F)
  • Allows calibration against NIST traceable standard reference material
  • 250 ml containers
Calibration solution (15 μS/cm) for conductivity sensors
Calibration standard (15 μS/cm) for conductivity sensors
Calibration solution (25 μS/cm) for conductivity sensors
Calibration standard (25 μS/cm) for conductivity sensors
Calibration solution (147 μS/cm) for conductivity sensors
Calibration standard (147 μS/cm) for conductivity sensors
Calibration solution (1413 μS/cm) for conductivity sensors
Calibration standard (1413 μS/cm) for conductivity sensors
Calibration solution (15 μS/cm) for conductivity sensors
Calibration solution (25 μS/cm) for conductivity sensors
Calibration solution (147 μS/cm) for conductivity sensors
Calibration solution (1413 μS/cm) for conductivity sensors

Related products

Water analysis panel

Multi-parameter measuring system for water quality monitoring

  • Flexibility in selecting different water parameters: dissolved oxygen, turbidity, conductivity, pH/ORP
  • Installation on compact analytical modules: All measuring points at one location
  • Completely pre-wired and pre-assembled for easy bypass installation
Conductivity sensor SMARTPAT COND 1200 – Standard version

Conductive conductivity sensor for water and wastewater applications

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: G¾ (male)
  • 0.1…20 mS/cm; Max. +135°C / +275°F; 16 bar / 232 psi
  • With stainless steel electrodes and Pt1000 for temperature compensation
Conductivity sensor SMARTPAT COND 3200 – Standard version

Conductive conductivity sensor for condensate, process, boiler feed or (ultra)pure water

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: G¾ (male), ¾ NPT (male)
  • 0.05…1000 μS/cm; Max. +135°C / +275°F; 16 bar / 232 psi
  • With stainless steel electrodes and Pt1000 for temperature compensation
Conductivity sensor SMARTPAT COND 5200 – Standard version

Conductive conductivity sensor for chemicals and industrial wastewater applications

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: G¾ (male), ¾ NPT (male)
  • 10 μS…15 mS/cm; Max. +130°C / +266°F; 16 bar / 232 psi
  • With graphite electrodes and Pt1000 for temperature compensation
Conductivity sensor SMARTPAT COND 7200 – Version with VARIVENT® connection

Conductive conductivity sensor for food, beverage and pharmaceutical applications

  • 2-wire loop powered, 4…20 mA/HART®7, for direct connection to a PCS
  • Process connection: VARIVENT® N, Tri-Clamp 1½", 2"
  • 0.05…1000 μS/cm; Max. +135°C / +275°F; 16 bar / 232 psi
  • With stainless steel electrodes (Ra <0.8 μm) and Pt1000 for temperature compensation
OPTISENS IND 1000 - Inductive conductivity sensor for water, wastewater and chemical applications

Inductive conductivity sensor for water, wastewater and chemical applications

  • For use with analytical transmitter
  • Process connection: G1½ union nut and immersion versions
  • 1…2000 mS/cm; Max. +100°C / +212°F
  • Electrodeless conductivity sensor with Pt1000 for temperature compensation
OPTISENS IND 7000 inductive conductivity sensor

Inductive conductivity sensor for food and beverage applications

  • For use with analytical transmitter
  • Process connection: G1½ (male, non-hygienic)
  • 0.5…2000 mS/cm; Max. +125°C / +257°F (for SIP/CIP); 10 bar / 145 psi
  • Sterilisable PEEK sensor (FDA and EC1935/2004 conform) with temperature compensation
Conductivity measuring system OPTISYS IND 7100 – Standard version

Inductive conductivity measuring system for food and beverage applications

  • 4-wire, 4…20 mA, with head-mounted transmitter
  • Process connection: Conical nozzle (DIN 11851) DN50
  • 0.5…2000 mS/cm; Max. +120°C / +248°F; 10 bar / 145 psi
  • PEEK sensor (FDA and EC1935/2004), with temperature compensation
OPTISYS IND 8100 – Inductive conductivity measuring system for food and beverage applications

Inductive conductivity measuring system for food and beverage applications

  • 4-wire, 4…20 mA, with head-mounted or remote transmitter
  • Process connection: G1 for hygienic adapters
  • 0.05…1000 mS/cm; Max. +140°C / +285°F; 25 bar / 362  psi
  • Hygienic PEEK sensor, robust (IP69K), with temperature compensation