pH buffer standard solution

Calibration solution for pH sensors

  • Available buffers: pH 4.0, pH 7.0 or pH 10.0
  • Accuracy: 0.01 pH units according to NIST (at +20°C / +68°F)
  • Coloured, ready-to-use reagent according to ISO 17025
  • 250 ml and 1 L containers
pH buffer solutions for calibration of pH sensors
Buffer solutions for ph 4, 7 and 10 – 1 L container
Blue pH 10 buffer solution – 1 L
pH 10 buffer solution for the calibration of pH sensors – 1 L container
Red pH 4 buffer solution – 1 L
pH 4 buffer solution for calibration of pH sensors – 1 L container
Blue pH 10 buffer solution – 250 ml
pH 10 buffer solution for calibration of pH sensors – 250 ml
Red pH 4 buffer solution – 250 ml
pH 4 buffer solution for calibration of pH sensors – 250 ml container
Yellow pH 7 buffer solution – 1 L
pH 7 buffer solution for calibration of pH sensors – 1 L container
Yellow pH 7 buffer solution – 250 ml
pH 7 buffer solution for calibration of pH sensors – 250 ml container
pH buffer solutions for calibration of pH sensors
Blue pH 10 buffer solution – 1 L
Red pH 4 buffer solution – 1 L
Blue pH 10 buffer solution – 250 ml
Red pH 4 buffer solution – 250 ml
Yellow pH 7 buffer solution – 1 L
Yellow pH 7 buffer solution – 250 ml

Related products

Water analysis panel

Multi-parameter measuring system for water quality monitoring

  • Flexibility in selecting different water parameters: dissolved oxygen, turbidity, conductivity, pH/ORP
  • Installation on compact analytical modules: All measuring points at one location
  • Completely pre-wired and pre-assembled for easy bypass installation
SMARTPAT PH 1590 pH sensor – Standard version

Potentiometric pH sensor for potable, process or treated water applications

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: ¾ NPT (male)
  • 0…14 pH; Max. +80°C / +176°F; 6.9 bar / 100 psi
  • With CPVC sensor body, ceramic diaphragm and Pt1000 for temperature compensation
SMARTPAT PH 2390 pH sensor – Standard version

Potentiometric pH sensor for municipal and industrial wastewater applications

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: ¾ NPT (male)
  • 0…14 pH; Max. +80°C / +176°F; 6.9 bar / 100 psi
  • With PPS sensor body, PTFE diaphragm and Pt1000 for temperature compensation
SMARTPAT PH 8150 pH sensor – Standard version

Potentiometric pH sensor for chemicals and industrial wastewater applications

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: PG13.5
  • 0…14 pH; Max. +130°C / +266°F; 12 bar / 174 psi
  • Glass sensor with open diaphragms and Pt1000 for temperature compensation
SMARTPAT PH 8320 pH sensor – Standard version

Potentiometric pH sensor for water and wastewater applications

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: PG13.5
  • 0…14 pH; Max. +70°C / +158°F; 10 bar / 145 psi
  • Glass sensor with PTFE diaphragm and Pt1000 for temperature compensation
SMARTPAT PH 8530 pH sensor – Standard version

Potentiometric pH sensor for pure water and low conductivity media (>2 μS/cm)

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: PG13.5
  • 0…14 pH; Max. +80°C / +176°F; 12 bar / 174 psi
  • Glass sensor with 3 ceramic diaphragms and Pt1000 for temperature compensation
SMARTPAT PH 8570 pH sensor – Standard version

Potentiometric pH sensor for food, beverage and pharmaceutical applications

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: PG13.5
  • 0…14 pH; Max. +140°C / +284°F (SIP/CIP); 12 bar / 174 psi
  • Autoclavable glass sensor with ceramic diaphragm and Pt1000 for temperature compensation
OPTISENS PH 8100 – Standard version

Potentiometric pH sensor for chemicals, industrial wastewater and low conductivity media (>2 μS/cm)

  • For use with analytical transmitter
  • Process connection: PG13.5
  • 0…14 pH; Max. +130°C / +266°F; 10 bar / 145 psi
  • Glass sensor with 2 open diaphragms and Pt100 for temperature compensation
OPTISENS PH 8300 – Standard version

Potentiometric pH sensor for wastewater, surface and process water applications

  • For use with analytical transmitter
  • Process connection: PG13.5
  • 0…14 pH; Max. +70°C / +158°F; 10 bar / 145 psi
  • Glass sensor with PTFE diaphragm and optional Pt100 for temperature compensation
OPTISENS PH 8390 – Standard version

Potentiometric pH sensor for municipal and industrial wastewater applications

  • For use with analytical transmitter
  • Process connection: ¾ NPT (male)
  • 0…14 pH; Max. +80°C / +176°F; 6.9 bar / 100 psi
  • With CPVC sensor body, PTFE diaphragm and Pt100 for temperature compensation
OPTISENS PH 8500 – Standard version

Potentiometric pH sensor for potable water applications

  • For use with analytical transmitter
  • Process connection: PG13.5
  • 0…14 pH; Max. +70°C / +158°F; 2 bar / 30 psi
  • Glass sensor with ceramic diaphragm and optional Pt100 for temperature compensation
OPTISENS PH 8590 – Standard version

Potentiometric pH sensor for water and wastewater applications

  • For use with analytical transmitter
  • Process connection: ¾ NPT (male)
  • 0…14 pH; Max. +80°C / +176°F; 6.9 bar / 100 psi
  • With CPVC sensor body, ceramic diaphragm and Pt100 for temperature compensation
OPTISENS PH 9100 – Standard version

Potentiometric pH sensor for lower conductivity water applications (>20 μS/cm)

  • For use with analytical transmitter
  • Process connection: PG13.5
  • 0…14 pH; Max. +100°C / +212°F; 1 bar / 14 psi
  • Liquid electrolyte glass sensor with open glass sleeve diaphragm
OPTISENS PH 9500 – Standard version

Potentiometric pH sensor for lower conductivity water applications (>50 μS/cm)

  • For use with analytical transmitter
  • Process connection: PG13.5
  • 0…14 pH; Max. +100°C / +212°F ; 1 bar / 14 psi
  • Liquid electrolyte glass sensor with 3 ceramic diaphragms