SENSOFIT IMM 2000

Immersion assembly for general water and wastewater treatment applications

  • For use with OPTISENS ODO/ADO/TUR 2000, OPTISENS  TSS 2000/3000 or sensors with NPT thread
  • Sensor connection: ¾ NPT, 1¼ NPT (female); Process connection: Telescopic rod holder mounted to handrail
  • Immersion length: flexible, max. 4 m / 13.1 ft
  • Max. +60°C / +140°F, pressureless
Immersion assembly for process analytics SENSOFIT IMM 2000 – Standard version
SENSOFIT IMM 2000 – Standard version

Related products

SMARTPAT PH 1590 pH sensor – Standard version

Potentiometric pH sensor for potable, process or treated water applications

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: ¾ NPT (male)
  • 0…14 pH; Max. +80°C / +176°F; 6.9 bar / 100 psi
  • With CPVC sensor body, ceramic diaphragm and Pt1000 for temperature compensation
SMARTPAT PH 2390 pH sensor – Standard version

Potentiometric pH sensor for municipal and industrial wastewater applications

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: ¾ NPT (male)
  • 0…14 pH; Max. +80°C / +176°F; 6.9 bar / 100 psi
  • With PPS sensor body, PTFE diaphragm and Pt1000 for temperature compensation
ORP sensor SMARTPAT ORP 1590 – Standard version

Potentiometric ORP sensor for water and wastewater applications

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: ¾ NPT (male)
  • -1500…+1500 mV; Max. +80°C / +176°F; 6.9 bar / 100 psi
  • Sensor with CPVC body, platinum electrode, ceramic diaphragm and Pt1000 temperature sensor
Conductivity sensor SMARTPAT COND 3200 – Standard version

Conductive conductivity sensor for condensate, process, boiler feed or (ultra)pure water

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: G¾ (male), ¾ NPT (male)
  • 0.05…1000 μS/cm; Max. +135°C / +275°F; 16 bar / 232 psi
  • With stainless steel electrodes and Pt1000 for temperature compensation
Conductivity sensor SMARTPAT COND 5200 – Standard version

Conductive conductivity sensor for chemicals and industrial wastewater applications

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: G¾ (male), ¾ NPT (male)
  • 10 μS…15 mS/cm; Max. +130°C / +266°F; 16 bar / 232 psi
  • With graphite electrodes and Pt1000 for temperature compensation
OPTISENS PH 8390 – Standard version

Potentiometric pH sensor for municipal and industrial wastewater applications

  • For use with analytical transmitter
  • Process connection: ¾ NPT (male)
  • 0…14 pH; Max. +80°C / +176°F; 6.9 bar / 100 psi
  • With CPVC sensor body, PTFE diaphragm and Pt100 for temperature compensation
OPTISENS PH 8590 – Standard version

Potentiometric pH sensor for water and wastewater applications

  • For use with analytical transmitter
  • Process connection: ¾ NPT (male)
  • 0…14 pH; Max. +80°C / +176°F; 6.9 bar / 100 psi
  • With CPVC sensor body, ceramic diaphragm and Pt100 for temperature compensation
OPTISENS ORP 8590 – Standard version

Potentiometric ORP sensor for water and wastewater applications

  • For use with analytical transmitter
  • Process connection: ¾ NPT (male)
  • -2000…+2000 mV; Max. +80°C / +176°F; 6.9 bar / 100 psi
  • Sensor with CPVC body, platinum electrode, ceramic diaphragm and Pt100 temperature sensor
OPTISENS TSS 2000

Optical total suspended solids sensor for wastewater applications

  • For use with MAC 100 analytical transmitter
  • For immersion
  • 0…4 AU, 0…18.5 g/l (sludge); max. +70°C / +158°F; 1 bar / 14 psi
  • Robust stainless steel sensor using single beam (180° NIR LED) principle, with optical sapphire glass windows
OPTISENS TSS 3000 – Standard version

Optical total suspended solids sensor for wastewater applications

  • For use with MAC 300 analytical transmitter
  • Process connection: 1¼ NPT (male)
  • 0…2.5, 10 or 25 g/l (sludge); Max. +85°C / +185°F; 10 bar / 145 psi
  • PP sensor using 4-beam alternating light principle, no optical windows, glass free
OPTISENS ADO 2000 – Standard version

Amperometric oxygen sensor for water and wastewater applications

  • For use with analytical transmitter
  • For immersion or insertion
  • 0…20 mg/l; Max. +50°C / +122°F; 6 bar / 87 psi
  • With stainless steel sensor body, rugged PTFE membrane, exchangeable electrode cartridge and temperature compensation
OPTISENS ODO 2000 optical oxygen sensor for water and wastewater applications

Optical oxygen sensor for water and wastewater applications

  • For use with analytical transmitter
  • For immersion or insertion
  • 0…20 mg/l; Max +50°C / +122°F; 6 bar / 87 psi
  • With rugged PVC sensor body, available with spray cleaning nozzle (immersion version)
OPTISENS TUR 2000 optical turbidity sensor for water and wastewater applications

Optical turbidity sensor for water and wastewater applications

  • For use with analytical transmitter
  • For immersion or insertion
  • 0…4/40/400  NTU/FNU; Max. +50°C / +122°F; 6 bar / 87 psi
  • 90° scattered light (NIR-LED) measurement acc. to ISO 7027