Calculation of thermowells in temperature measurement

In temperature measuring devices, thermowells form the interface between the sensing element and the process. They protect the actual probe while they themselves are exposed to thermal, chemical and mechanical stresses.
Vibration load visualisation
Vibration load diagram
Resistance (RTD) temperature assembly OPTITEMP TRA-G20 – Standard version

For the safe operation of temperature measurements with thermowells, the following must be observed:

Thermowells are placed in a state of spatial stress by static pressure. Bending and shear stresses are added when flow is applied.

Behind flow-loaded thermowells, vortices are periodically detached. However, this effect, which is required for vortex flow meters, also leads to undesired oscillations of the thermowell and thus to its destruction if the frequency of the vortices does not deviate significantly from the resonant frequency of the thermowell.

For strength calculations, all stresses are combined into one equivalent stress, which should have a safety factor > 1.7 with respect to the hot yield strength or the creep strength of the material.

The risk of a thermowell failure can be significantly reduced by calculating the stresses prior to design.

Products

Filter

71 products
Product name

OPTITEMP TRA-H61 hygienic RTD sensor
OPTITEMP TRA-H61

Resistance (RTD) temperature assembly for hygienic applications

OPTITEMP TRA-H65 hygienic RTD sensor
OPTITEMP TRA-H65

Resistance (RTD) temperature assembly for hygienic applications

Resistance (RTD) temperature assembly OPTITEMP TRA-F13 – Standard version
OPTITEMP TRA-F13

Resistance (RTD) temperature assembly for standard applications

Resistance (RTD) temperature assembly OPTITEMP TRA-F23 – Standard version
OPTITEMP TRA-F23

Resistance (RTD) temperature assembly for standard applications

Resistance (RTD) temperature assembly OPTITEMP TRA-F42 – Standard version
OPTITEMP TRA-F42

Resistance (RTD) temperature assembly for standard applications

Resistance (RTD) temperature assembly OPTITEMP TRA-G10 – Standard version
OPTITEMP TRA-G10

Resistance (RTD) temperature assembly for surface temperature measurement in industrial applications

Resistance (RTD) temperature assembly OPTITEMP TRA-G20 – Standard version
OPTITEMP TRA-G20

Resistance (RTD) temperature assembly for surface temperature measurement on double-walled pipes or similar applications

Resistance (RTD) temperature assembly OPTITEMP TRA-H10 – Version with Tri-Clamp connection
OPTITEMP TRA-H10

Resistance (RTD) temperature assembly for hygienic applications

Resistance (RTD) temperature assembly OPTITEMP TRA-H20 – Version with Varivent®  connection
OPTITEMP TRA-H20

Resistance (RTD) temperature assembly for hygienic applications

Resistance (RTD) temperature assembly OPTITEMP TRA-H30 – Version with Tri-Clamp connection
OPTITEMP TRA-H30

Resistance (RTD) temperature assembly for hygienic applications

Resistance (RTD) temperature assembly OPTITEMP TRA-P10 – Standard version
OPTITEMP TRA-P10

Resistance (RTD) temperature assembly for standard applications

Resistance (RTD) temperature assembly OPTITEMP TRA-P14 – Standard version
OPTITEMP TRA-P14

Resistance (RTD) temperature assembly for standard applications or use in existing thermowells

Resistance (RTD) temperature assembly OPTITEMP TRA-P20 – Standard version
OPTITEMP TRA-P20

Resistance (RTD) temperature assembly for standard applications

Resistance (RTD) temperature assembly OPTITEMP TRA-P40 – Standard version
OPTITEMP TRA-P40

Resistance (RTD) temperature assembly for standard applications

Resistance (RTD) temperature assembly OPTITEMP TRA-S11 – Standard version
OPTITEMP TRA-S11

Resistance (RTD) temperature assembly for lower temperature applications

Resistance (RTD) temperature assembly OPTITEMP TRA-S12 – Standard version
OPTITEMP TRA-S12

Resistance (RTD) temperature assembly for standard applications

Resistance (RTD) temperature assembly OPTITEMP TRA-S21 – Standard version
OPTITEMP TRA-S21

Resistance (RTD) temperature assembly for lower temperature applications

Resistance (RTD) temperature assembly OPTITEMP TRA-S22 – Standard version
OPTITEMP TRA-S22

Resistance (RTD) temperature assembly for standard applications

Resistance (RTD) temperature assembly OPTITEMP TRA-S34 – Standard version
OPTITEMP TRA-S34

Resistance (RTD) temperature assembly for use in existing thermowells or machinery

Resistance (RTD) temperature assembly OPTITEMP TRA-S41 – Standard version
OPTITEMP TRA-S41

Resistance (RTD) temperature assembly for standard applications

Resistance (RTD) temperature assembly OPTITEMP TRA-S50 – Standard version
OPTITEMP TRA-S50

Resistance (RTD) temperature assembly for use in existing thermowells or machinery

Resistance (RTD) temperature assembly OPTITEMP TRA-T30 – Standard version
OPTITEMP TRA-T30

Resistance (RTD) temperature assembly for higher flow velocities and pressures

Resistance (RTD) temperature assembly OPTITEMP TRA-TF31 – Standard version
OPTITEMP TRA-TF31

Resistance (RTD) temperature assembly for higher flow velocities and pressures

Resistance (RTD) temperature assembly OPTITEMP TRA-TF33 – Standard version
OPTITEMP TRA-TF33

Resistance (RTD) temperature assembly for higher flow velocities and pressures


Showing 24 of 71

Show more