OPTIBAR MR 4300
Orifice meter run with corner taps and annular chambers
- Completely pre-assembled with orifice plate, piping, inlet/outlet sections, process connections
- Size: DN15…100 / ½…4"; up to PN100 / ASME Cl 1500
- Temperature: max. +400°C / +752°F
- Material: 1.4404 / 316L
Overview
The OPTIBAR MR 4300 is an orifice meter run. It is ideally suitable for use in small line sizes (
It comes completely pre-assembled and ready for installation, with orifice plate, annular chambers, process connections as well as inlet and outlet sections for low-disturbance flow. The DP flow element is available with the OPTIBAR DP 7060 DP pressure transmitter as well as with manifolds, valves, condensate pots or other accessories.
Features & Options
Product features and options depend on device configuration: Contact us to make sure that your preferred functionality can be combined in one device.
- Compact or separate design
- Upstream and downstream sections acc. to DIN 19214
- Reduces flow disturbances
- Minimum measurement uncertainties: ±0.3…0.4% (calibrated)
- Optional water-calibrated version for increased accuracy (±0.3%)