FGD wastewater treatment in biomass power plant
FGD wastewater treatment in biomass power plant – Flow measurement of waste water
FGD wastewater treatment in biomass power plant – Level measurement in seperator
FGD wastewater treatment in biomass power plant – Sludge level measurement
FGD wastewater treatment in biomass power plant – Flow measurement of pre clarified waste water
FGD wastewater treatment in biomass power plant – Level measurement at sludge thickner
FGD wastewater treatment in biomass power plant – Dosing of oxidant, flocculant and other chemicals
FGD wastewater treatment in biomass power plant – Flow measurement of pre clarified waste water
FGD wastewater treatment in biomass power plant – Sludge level measurement in sedimentation
FGD wastewater treatment in biomass power plant – Quality measurement of clarified water
FGD wastewater treatment in biomass power plant – Level measurement of overflow channel
FGD wastewater treatment in biomass power plant – Flow measurement of preclarified waste water
FGD wastewater treatment in biomass power plant – Level measurement of sludge thickner
FGD wastewater treatment in biomass power plant – Sludge level measurement in sedimentation 2
FGD wastewater treatment in biomass power plant – Level measurement at sludge thickner
FGD wastewater treatment in biomass power plant – Quality measurement of clarified water
FGD wastewater treatment in biomass power plant – Level measurement of overflow channel
FGD wastewater treatment in biomass power plant – Level measurement of equalization tank
FGD wastewater treatment in biomass power plant – Flow for reuse or preflooder
FGD wastewater treatment in biomass power plant – Quality measurement for sludge conditioning
FGD wastewater treatment in biomass power plant – Level measurement of treatment tank
FGD wastewater treatment in biomass power plant – Level measurement of filtrate tank
FGD wastewater treatment in biomass power plant – Flow measurement of filtrate
FGD wastewater treatment in biomass power plant – Analyzer house for FGD water treatment plant
FGD wastewater treatment in biomass power plant

Description

Durchflussmessung von Abwasser

Anforderungen

  • Unempfindlich gegenüber Ablagerungen

Description

Füllstandmessung in Abscheider

Anforderungen

  • Prozesssteuerung

Description

Schlammspiegelmessung

Anforderungen

  • Tauchsonde

Description

Durchflussmessung von vorgeklärtem Abwasser

Anforderungen

  • Unempfindlich gegenüber Ablagerungen

Description

Füllstandmessung an Schlammeindicker

Anforderungen

  • Prozesssteuerung

Description

Dosierung von Oxidationsmittel, Flockungsmittel und anderen Chemikalien

Anforderungen

  • Geringer Wartungsbedarf
  • Keine Drift

Description

Durchflussmessung von vorgeklärtem Abwasser

Anforderungen

  • Unempfindlich gegenüber Ablagerungen

Description

Schlammspiegelmessung in Sedimentation

Anforderungen

  • Tauchsonde

Description

Qualitätsmessung von geklärtem Wasser

Anforderungen

  • Geringer Wartungsbedarf

Description

Füllstandmessung von Überlaufkanal

Anforderungen

  • Wartungsfrei

Description

Durchflussmessung von vorgeklärtem Abwasser

Anforderungen

  • Prozesssteuerung

Description

Füllstandmessung von Schlammeindicker

Anforderungen

  • Prozesssteuerung

Description

Schlammspiegelmessung in Sedimentation 2

Anforderungen

  • Tauchsonde

Description

Füllstandmessung an Schlammeindicker

Anforderungen

  • Prozesssteuerung

Description

Qualitätsmessung von geklärtem Wasser

Anforderungen

  • Geringer Wartungsbedarf

Description

Füllstandmessung von Überlaufkanal

Anforderungen

  • Wartungsfrei

Description

Füllstandmessung von Ausgleichstank

Anforderungen

  • Wartungsfrei
  • Hohe Feuchtigkeit

Description

Durchfluss für Wiederverwendung oder Vorfluter

Anforderungen

  • Lokale Anforderungen an eichpflichtigen Verkehr

Description

Qualitätsmessung für Schlammkonditionierung

Anforderungen

  • Geringer Wartungsbedarf

Description

Füllstandmessung von Aufbereitungstank

Anforderungen

  • Wartungsfrei
  • Hohe Feuchtigkeit

Description

Füllstandmessung von Filtrattank

Anforderungen

  • Wartungsfrei
  • Hohe Feuchtigkeit

Description

Durchflussmessung von Filtrat

Anforderungen

  • Prozesssteuerung

Description

Analysegehäuse für REA Wasseraufbereitungsanlage

Anforderungen

  • Komplettes System betriebsbereit
  • Prozesssteuerung

Übersicht

REA Abwasserbehandlung in Biomasse-Kraftwerk

Instrumentierung für die Wasseraufbereitung

Abwasser aus der Rauchgasentschwefelung (REA) aus feststoffbefeuerten Kraftwerken ist häufig mit Calciumsulfat gesättigt und enthält sowohl Metalle als auch Chloride. Der Verfahrensschritte bei der Behandlung müssen an das jeweilige Abwasser angepasst werden und bestehen oft aus chemischer Behandlung, Flockung, Klärung und Filtration. Das Wasser kann im Prozess wiederverwendet oder für höhere Anforderungen weiter gereinigt werden.

Insbesondere bei diesen Prozessen mit Sedimentation ist eine zuverlässige Messung des Schlammspiegels und Schlammprofils von grundlegender Bedeutung für eine sichere Leistung des Klärbeckens und eine effiziente Nutzung des Flockungsmittels. Mit dem OPTISENS TSS/MAC und OPTISYS SLM stehen neben einer Reihe von robusten und korrosionsbeständigen Geräten für die Messung von Durchfluss, Füllstand, Druck und Temperatur verschiedene Analysegeräten und Systeme für die Messung von Feststoff-Trennschicht und -Profil zur Verfügung.