OPTISOUND 3010C - 3030C
Ultrasonic Level Gauge for liquids
Application range
OPTISOUND 3010 C, 3020 C and 3030 C ultrasonic sensors are especially suitable for level measurement of liquids, but a real so good for solids. The instruments differ in the measuring range, the transducer version and the process fitting.
Through different, adapted emitting frequencies, levels in a measuring range of 0.25 m ... 15 m (0.82 ft ... 49.2 ft) can be measured.
Resistant materials for transducers and process fittings also allowa pplications in corrosive products (depending on the model).
A practical mounting strap (option) enables easy orientation of OPTISOUND 3030 C.
 | Level measurement during processing and storage of liquids
|  | Sumps, water and wastewater basins
|  | Noncontact flow measurement and detection inopen channels |
OPTISOUND 3010 CThe application range covers liquids and solids in virtually all industries, especially in the water and sewage water treatment treatment.
Technical data (extract)| Measuring range | liquids: | 0.25 - 5 m | | | solids: | 0.25 - 2 m | | Process connection | | G1½A of PVDF | | Process temperature | | -40 - 80°C | | Process pressure | | -0.2 - 2 bar |
OPTISOUND 3020 CThe application range covers liquids and solids in virtually all industries, especially in the water and sewage water treatment treatment.
Technical data (extract)| Masuring range | liquids: | 0.4 - 8 m | | | solids: | 0.4 - 3.5 m | | Process connection | | G2A of PVDF | | Process temperature | | -40 - 80°C | | Process pressure | | -0.2 - 2 bar |
OPTISOUND 3030 CThe application range covers liquids and solids in virtually all industries.
Technical data (extract)| Measuring range | liquids: | 0.6 - 15 m | | | solids: | 0.6 - 7 m | | Process connection | | compression flange or mounting strap | | Process temperature | | -40 - 80°C | | Process pressure | | -0.2 - 1 bar |
|