HomeCompanyProductsIndustriesServiceDownloadNewsCountriesContact

 
EMF / Magmeters
Variable Area Flowmeters
Metal Cone
H250 M40
H250 M8
H250 M9
H250 M10
H250 Food | Pharmaceutical
H250 – Specials
DK 32 | DK 34
DK 37
Glass Cone
Plastics
Pressure regulators
Measuring Principle
Ultrasonic Flowmeters
Mass Flowmeters
Vortex Flowmeters
Flow Controllers
Level Measurement
Temperature & Pressure
Analysis
Batching Controller
Complete Batching Systems
Exi Controller
Exi Indicator
Communications
Loading Software

H250 with M40 indicator


The new standard solution for the process industry

The H250/M40 flowmeters are setting a new standard in variable area flowmeter technology. They combine tried and tested flow measurement with latest communication capabilities like Foundation Fieldbus. The functionality of the devices is modular extendable. The innovative construction allows a free choice of intrinsically safe or flameproof design.

The sturdy all-metal design, availabale in different materials, ensures high resistance to pressure, temperature and media and stands up to extreme application and environmental conditions. The new H250/M40 is the new standard solution for the process industry when costs and reliability are a factor.


Highlights indicator/transmitter M40
Simple, low-cost installation: Measure and display without auxiliary power supply 
Unique modularity to adapt to customer-specific applications
limit switches (NAMUR, 3-wire transistor or reed contacts)
2-wire analog output 4…20mA with HART
Foundation Fieldbus / Profibus PA interface
Graphical LC display with flow counter and pulse output 
Universal ex-concept: Flameproof and intrinsically safe
Ingress protection IP66/67, Nema 4x/6
Any meter orientation possible: vertical, horizontal or in fall pipes


Highlights H 250 measuring cone
Sturdy stainless steel construction for high operating pressure up to 3000 bar and extreme process temperatures from -200°C to +400°C
Optionally available with PTFE/ceramic liner for acids and alkalis 
High application security, even with extremely small flows 
Excellent long-term stability 
Upper limit of measurement for liquids: 10 to 120,000 l/h (water: 20°C) 
Upper limit of measurement for gases: 0.7 to 2800 m3/h (air: 20°C, 1.013 bar) 
Measuring range 10:1 (optional 100:1)
Accuracy: 1.6 % according VDI/VDE 3513-2 (qG = 50%) 
Many different process connections
Flanges as per EN (DN15-DN150), ASME and JIS
Screw and clamp connections, welding ends et al.
Special design for the food and pharmaceutical industry with EHEDG approval 


Further options (also for retrofit)
Magnetic filters, if the medium contains particles which can be magnetically influenced
Float damping for pulsating flows or low operating pressure (especially when measuring gases) 
Display damping ensures measured value is easy to read
Heating jacket for measuring cone

Video Variable Area Flowmeters



open video >>
(ca. 3 min run time)

Downloadcenter


H250