HomeCompanyProductsIndustriesServiceDownloadNewsCountriesContact

 
EMF / Magmeters
Variable Area Flowmeters
Metal Cone
Glass Cone
VA 40
VA 45
GA 24
DK 46 | 47 | 48 | 800
DK 700
Plastics
Pressure regulators
Measuring Principle
Ultrasonic Flowmeters
Mass Flowmeters
Vortex Flowmeters
Flow Controllers
Level Measurement
Temperature & Pressure
Analysis
Batching Controller
Complete Batching Systems
Exi Controller
Exi Indicator
Communications
Loading Software

DK 46 | 47 | 48 | 800


Small flowmeters (glass)

The DK 46, DK 47, DK 48 and DK 800 variable area flowmeters feature glass cones of varying lengths for different accuracy requirements.

The medium is visible and the flow value of the gas or liquid can be read directly off the scale at the height of the float.




It is easy to change the measuring glass, which is protected by a plastic cover, without disassembling the fitting.

For precise setting of the flow value, all devices are equipped with a metering valve.

Highlights
Simple, low-cost measuring principle without auxiliary power 
Stainless steel, brass or PVDF fittings 
Needle valve in foot or head piece 
Process temperatures: -5°C to +100°C 
Operating pressure up to 10 bar 
Upper limit of measurement for liquids: 0.4 to 160 l/h (water: 20°C) 
Upper limit of measurement for gases: 5 to 5,000 l/h (air: 20°C, 1.013 bar) 
2 limit switches (ring initiators) 
Accuracy 1.0 % - 4.0% of measured value acc. VDI/VDE 3513-2 (qG=50%) (depending on length of cone) 
Use in hazardous areas (ATEX) 
Many different process connections 

The devices are especially well suited to measuring carrier gases in gas chromatography, for display, monitoring and dosing of gases in production processes as well as measuring liquids and gases in laboratories and pilot installations.

Blinds and supports are available for panel mounting. By using a lab foot, the flowmeters can be converted into standard devices. KROHNE also supplies fully assembled, customer-specific dosing panels.


Differential pressure regulators
It is possible to directly connect a differential pressure regulator in order to ensure constant flow in the event of fluctuating operating pressure.

A small flowmeter, DK 46, is available with the type designation DKR46. It has been combined with a flow controller for incoming pressure into a compact device.